Product Description

Basic Information

Origin
China
HS Code
8504401990

Product Description

Input Features

Item Parameters Remark
Operating Voltage (AC) 285~475V, rated voltage 380V See input voltage/output power curve
Input Frequency (HZ) 45~55 -
Power Factor Full load ≥ 0.99 -
THD Full load ≤ 5% -
Standby Power Consumption < 12W -
Input voltage/output power curve
Input voltage / output power curve

Output Features

Item Parameter Remark
Output Voltage Range (DC) 150~1000V -
Max Output Current (A) 120 -
Output Constant Power Interval 250~500VDC, 500~1000VDC -
Output Current Limit Range Max limit 120A, set between 2~120A See output voltage/current curve
Voltage Stabilization Accuracy ≤±0.5% -
Current Stabilization Accuracy ≤±1% (load current 20%~100%) -
Output Ripple Coefficient ≤±0.5% -
Parallel Current Sharing Imbalance ≤±5% (average current > 5A) -
Peak Efficiency ≥95.5% -
Soft Start Time (S) 3~8 -
Anti-Current Rewinding Support -
Communication Protocol CAN -
Output voltage/output current
Output voltage / output current

Quality & Manufacturing

CE Certificate

CE Certificate

Manufacturing Center

Manufacturing Center

Test Center Facilities

18m³ Walk-in High/Low Temperature Lab
18m³ walk-in high and low temperature lab
Anechoic Chamber
Anechoic Chamber (FARNKONIA) for CISPR/IEC testing
Test Hall
Test hall with AC power supply & DC electronic load

Frequently Asked Questions

What is the rated input voltage for this module?
The rated input voltage is 380V AC, with an operating range between 285V and 475V.
What is the maximum output current capacity?
The module supports a maximum output current of 120A, with an adjustable limit range between 2A and 120A.
Does the system support parallel operation with multiple modules?
Yes, it supports parallel configurations with a current sharing imbalance of ≤±5% when the average current is above 5A.
What is the peak efficiency of this power module?
The module achieves a peak efficiency of ≥95.5%, ensuring minimal energy loss during operation.
Is there protection against current rewinding?
Yes, the system is designed to support the prevention of current rewinding during output.
What communication protocol is used for monitoring?
The module utilizes the CAN (Controller Area Network) communication protocol for robust data exchange.